Simultaneous Voltammetric Determination of Heavy Metals by Use of Crown Ether-modified Electrodes and Chemometrics

Andreu González-Calabuig, David Guerrero, Núria Serrano Plana, Manel del Valle*

*Autor correspondiente de este trabajo

Producción científica: Contribución a una revistaArtículoInvestigaciónrevisión exhaustiva

35 Citas (Scopus)

Resumen

A three-sensor array consisting of a graphite-epoxy composite electrode (GEC), 4-carboxybenzo-18-crown-6-GEC and 4-carboxybenzo-15-crown-5-GEC was employed for the simultaneous determination of Cd(II), Pb(II) and Hg(II) by differential pulse anodic stripping voltammetry (DPASV). Sensors were firstly studied for the determination of Hg(II); secondly, peak current responses confirmed that all sensors showed differentiated response for the three considered metals. A response model was developed to resolve mixtures of Cd(II), Pb(II) and Hg(II) at the μg L-1 level; Discrete Wavelet Transform was selected as preprocessing tool and artificial neural network used for the modelling of the obtained responses.

Idioma originalInglés
Páginas (desde-hasta)663-670
Número de páginas8
PublicaciónElectroanalysis
Volumen28
N.º4
DOI
EstadoPublicada - 1 abr 2016

Huella

Profundice en los temas de investigación de 'Simultaneous Voltammetric Determination of Heavy Metals by Use of Crown Ether-modified Electrodes and Chemometrics'. En conjunto forman una huella única.

Citar esto