TY - JOUR
T1 - Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty
AU - Hernandez-Vaquero, Daniel
AU - Abat, Ferran
AU - Sarasquete, Juan
AU - Monllau, Juan Carlos
PY - 2013/10/18
Y1 - 2013/10/18
N2 - AIM: To investigate the correlation between preoperative measurement in total knee arthroplasty and the prosthetic size implanted. METHODS: A prospective double-blind study of 50 arthroplasties was performed. Firstly, the reliability and correspondence between the size of said measurement and the actual implant utilized was determined. Secondly, the existing correlation between the intra- and interobserver determinations with the intraclass correlation coefficient was analyzed. RESULTS: An overall correspondence of 54%, improving up to 92% when the measured size admitted a difference of one size, was found. Good intra- and interobserver reliability with an intraclass correlation coefficient greater than 0.90 (P < 0.001) was also discovered. CONCLUSION: Agreement between the preoperative measurement with standardized acetate templates and the prosthetic size implanted can be considered satisfactory. We thus conclude it is a reproducible technique. © 2013 Baishideng.
AB - AIM: To investigate the correlation between preoperative measurement in total knee arthroplasty and the prosthetic size implanted. METHODS: A prospective double-blind study of 50 arthroplasties was performed. Firstly, the reliability and correspondence between the size of said measurement and the actual implant utilized was determined. Secondly, the existing correlation between the intra- and interobserver determinations with the intraclass correlation coefficient was analyzed. RESULTS: An overall correspondence of 54%, improving up to 92% when the measured size admitted a difference of one size, was found. Good intra- and interobserver reliability with an intraclass correlation coefficient greater than 0.90 (P < 0.001) was also discovered. CONCLUSION: Agreement between the preoperative measurement with standardized acetate templates and the prosthetic size implanted can be considered satisfactory. We thus conclude it is a reproducible technique. © 2013 Baishideng.
KW - Correlation coefficient
KW - Preoperative measurement
KW - Prosthetic size
KW - Templating
KW - Total knee arthroplasty
U2 - 10.5312/wjo.v4.i4.287
DO - 10.5312/wjo.v4.i4.287
M3 - Article
SN - 2218-5836
VL - 4
SP - 287
EP - 290
JO - World Journal of Orthopaedics
JF - World Journal of Orthopaedics
IS - 4
ER -