Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty

Daniel Hernandez-Vaquero, Ferran Abat, Juan Sarasquete, Juan Carlos Monllau

Producción científica: Contribución a una revistaArtículoInvestigaciónrevisión exhaustiva

15 Citas (Scopus)

Resumen

AIM: To investigate the correlation between preoperative measurement in total knee arthroplasty and the prosthetic size implanted. METHODS: A prospective double-blind study of 50 arthroplasties was performed. Firstly, the reliability and correspondence between the size of said measurement and the actual implant utilized was determined. Secondly, the existing correlation between the intra- and interobserver determinations with the intraclass correlation coefficient was analyzed. RESULTS: An overall correspondence of 54%, improving up to 92% when the measured size admitted a difference of one size, was found. Good intra- and interobserver reliability with an intraclass correlation coefficient greater than 0.90 (P < 0.001) was also discovered. CONCLUSION: Agreement between the preoperative measurement with standardized acetate templates and the prosthetic size implanted can be considered satisfactory. We thus conclude it is a reproducible technique. © 2013 Baishideng.
Idioma originalInglés
Páginas (desde-hasta)287-290
PublicaciónWorld Journal of Orthopaedics
Volumen4
N.º4
DOI
EstadoPublicada - 18 oct 2013

Huella

Profundice en los temas de investigación de 'Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty'. En conjunto forman una huella única.

Citar esto