Predicting herbivore faecal nitrogen using a multispecies near-infrared reflectance spectroscopy calibration

Miriam Villamuelas, Emmanuel Serrano, Johan Espunyes, Néstor Fernández, Jorge R. López-Olvera, Mathieu Garel, João Santos, María Ángeles Parra-Aguado, Maurizio Ramanzin, Xavier Fernández-Aguilar, Andreu Colom-Cadena, Ignasi Marco, Santiago Lavín, Jordi Bartolomé, Elena Albanell

Producción científica: Contribución a una revistaArtículoInvestigaciónrevisión exhaustiva

26 Citas (Scopus)

Resumen

© 2017 Villamuelas et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Optimal management of free-ranging herbivores requires the accurate assessment of an animal's nutritional status. For this purpose 'near-infrared reflectance spectroscopy' (NIRS) is very useful, especially when nutritional assessment is done through faecal indicators such as faecal nitrogen (FN). In order to perform an NIRS calibration, the default protocol recommends starting by generating an initial equation based on at least 50-75 samples from the given species. Although this protocol optimises prediction accuracy, it limits the use of NIRS with rare or endangered species where sample sizes are often small. To overcome this limitation we tested a single NIRS equation (i.e., multispecies calibration) to predict FN in herbivores. Firstly, we used five herbivore species with highly contrasting digestive physiologies to build monospecies and multispecies calibrations, namely horse, sheep, Pyrenean chamois, red deer and European rabbit. Secondly, the equation accuracy was evaluated by two procedures using: (1) an external validation with samples from the same species, which were not used in the calibration process; and (2) samples from different ungulate species, specifically Alpine ibex, domestic goat, European mouflon, roe deer and cattle. The multispecies equation was highly accurate in terms of the coefficient of determination for calibration R2 = 0.98, standard error of validation SECV = 0.10, standard error of external validation SEP = 0.12, ratio of performance to deviation RPD = 5.3, and range error of prediction RER = 28.4. The accuracy of the multispecies equation to predict other herbivore species was also satisfactory (R2 > 0.86, SEP < 0.27, RPD > 2.6, and RER > 8.1). Lastly, the agreement between multi- and monospecies calibrations was also confirmed by the Bland-Altman method. In conclusion, our single multispecies equation can be used as a reliable, cost-effective, easy and powerful analytical method to assess FN in a wide range of herbivore species.
Idioma originalInglés
Número de artículoe0176635
PublicaciónPLoS ONE
Volumen12
N.º4
DOI
EstadoPublicada - 1 abr 2017

Huella

Profundice en los temas de investigación de 'Predicting herbivore faecal nitrogen using a multispecies near-infrared reflectance spectroscopy calibration'. En conjunto forman una huella única.

Citar esto