Municipal sewer networks as sources of nitrous oxide, methane and hydrogen sulphide emissions: A review and case studies

Elena Eijo-Río, Anna Petit-Boix, Gara Villalba, María Eugenia Suárez-Ojeda, Desirée Marin, Maria José Amores, Xavier Aldea, Joan Rieradevall, Xavier Gabarrell

Producción científica: Contribución a una revistaArtículo de revisiónInvestigaciónrevisión exhaustiva

53 Citas (Scopus)

Resumen

© 2015 Elsevier Ltd. All rights reserved. Sewers are known as longitudinal reactors where gases such as methane, nitrous oxide and hydrogen sulphide can be produced. However, gaseous emissions have been mainly assessed in wastewater treatment plants (WWTP). This article presents a critical review of studies that quantify the generation of these gases in sewers and aims to identify the existing research gaps. Differences in sampling methods and site selection, as well as a limited number of studies, result in incoherent comparisons. To address some of these gaps, sampling campaigns were conducted in two Spanish cities. Results showed that wet wells were the most important sources of gases with concentrations up to 321 μg CH<inf>4</inf> L<inf>air</inf><sup>-1</sup> and 6.8 μg N<inf>2</inf>O L<inf>air</inf><sup>-1</sup>. Regarding emission factors, in the case of Calafell, the estimated annual emissions were 18.6 kg CH<inf>4</inf> year<sup>-1</sup> and 0.3 kg H<inf>2</inf>S year<sup>-1</sup> in summer and 3.8 kg CH<inf>4</inf> year<sup>-1</sup> and 0.5 kg H<inf>2</inf>S year<sup>-1</sup> in winter. About Betanzos, these values were 24.6 kg CH<inf>4</inf> year<sup>-1</sup> and 0.5 kg N<inf>2</inf>O year<sup>-1</sup> in summer and 10 kg CH<inf>4</inf> year<sup>-1</sup> in winter. The summer campaign resulted in greater gas concentration than in the winter season for both cities, suggesting that temperature is a key parameter. We conclude that gas emissions from sewers are significant compared to those of WWTPs resulting in an important contribution to the carbon footprint. Further work needs to be done to assess the gas production along the entire sewer networks, which can result in very different emission factors depending on the sewer components.
Idioma originalInglés
Páginas (desde-hasta)2084-2094
PublicaciónJournal of Environmental Chemical Engineering
Volumen3
N.º3
DOI
EstadoPublicada - 3 ago 2015

Huella

Profundice en los temas de investigación de 'Municipal sewer networks as sources of nitrous oxide, methane and hydrogen sulphide emissions: A review and case studies'. En conjunto forman una huella única.

Citar esto