TY - JOUR
T1 - Multi-wavelength high-performance liquid chromatographic fingerprints and chemometrics to predict the antioxidant activity of Turnera diffusa as part of its quality control
AU - Lucio-Gutiérrez, J. Ricardo
AU - Garza-Juárez, Aurora
AU - Coello, J.
AU - Maspoch, S.
AU - Salazar-Cavazos, M. L.
AU - Salazar-Aranda, Ricardo
AU - Waksman de Torres, Noemi
PY - 2012/4/27
Y1 - 2012/4/27
N2 - The determination of the antioxidant activity of Turnera diffusa using partial least squares regression (PLSR) on chromatographic data is presented. The chromatograms were recorded with a diode array detector and, for each sample, an enhanced fingerprint was constructed by compiling into a single data vector the chromatograms at four wavelengths (216, 238, 254 and 345. nm). The wavelengths were selected from a contour plot, in order to obtain the greater number of peaks at each of the wavelengths. A further pretreatment of the data that included baseline correction, scaling and correlation optimized warping was performed. Optimal values of the parameters used in the warping were found by means of simplex optimization. A PLSR model with four latent variables (LV) explained 52.5% of X variance and 98.4% of Y, with a root mean square error for cross validation of 6.02. To evaluate its reliability, it was applied to an external prediction set, retrieving a relative standard error for prediction of 7.8%. The study of the most important variables for the regression indicated the chromatographic peaks related to antioxidant activity at the used wavelengths. © 2012 Elsevier B.V.
AB - The determination of the antioxidant activity of Turnera diffusa using partial least squares regression (PLSR) on chromatographic data is presented. The chromatograms were recorded with a diode array detector and, for each sample, an enhanced fingerprint was constructed by compiling into a single data vector the chromatograms at four wavelengths (216, 238, 254 and 345. nm). The wavelengths were selected from a contour plot, in order to obtain the greater number of peaks at each of the wavelengths. A further pretreatment of the data that included baseline correction, scaling and correlation optimized warping was performed. Optimal values of the parameters used in the warping were found by means of simplex optimization. A PLSR model with four latent variables (LV) explained 52.5% of X variance and 98.4% of Y, with a root mean square error for cross validation of 6.02. To evaluate its reliability, it was applied to an external prediction set, retrieving a relative standard error for prediction of 7.8%. The study of the most important variables for the regression indicated the chromatographic peaks related to antioxidant activity at the used wavelengths. © 2012 Elsevier B.V.
KW - Antioxidant activity
KW - Chemometrics
KW - HPLC-fingerprints
KW - Multi-wavelength
KW - Turnera diffusa
U2 - 10.1016/j.chroma.2012.02.042
DO - 10.1016/j.chroma.2012.02.042
M3 - Article
SN - 0021-9673
VL - 1235
SP - 68
EP - 76
JO - Journal of Chromatography
JF - Journal of Chromatography
ER -