Resumen
Mechanical ventilation with a tidal volume (V) of 6 mL/kg/predicted body weight (PBW), to maintain plateau pressure (P) lower than 30 cmHO, does not completely avoid the risk of ventilator induced lung injury (VILI). The aim of this study was to evaluate safety and feasibility of a ventilation strategy consisting of very low V combined with extracorporeal carbon dioxide removal (ECCOR). In fifteen patients with moderate ARDS, V was reduced from baseline to 4 mL/kg PBW while PEEP was increased to target a plateau pressure - (P) between 23 and 25 cmHO. Low-flow ECCOR was initiated when respiratory acidosis developed (pH < 7.25, PaCO > 60 mmHg). Ventilation parameters (V, respiratory rate, PEEP), respiratory compliance (C), driving pressure (DeltaP = V/C), arterial blood gases, and ECCOR system operational characteristics were collected during the period of ultra-protective ventilation. Patients were weaned from ECCOR when PaO/FiO was higher than 200 and could tolerate conventional ventilation settings. Complications, mortality at day 28, need for prone positioning and extracorporeal membrane oxygenation, and data on weaning from both MV and ECCOR were also collected. During the 2 h run in phase, V reduction from baseline (6.2 mL/kg PBW) to approximately 4 mL/kg PBW caused respiratory acidosis (pH < 7.25) in all fifteen patients. At steady state, ECCOR with an average blood flow of 435 mL/min and sweep gas flow of 10 L/min was effective at correcting pH and PaCO to within 10 % of baseline values. PEEP values tended to increase at V of 4 mL/kg from 12.2 to 14.5 cmHO, but this change was not statistically significant. Driving pressure was significantly reduced during the first two days compared to baseline (from 13.9 to 11.6 cmHO; p < 0.05) and there were no significant differences in the values of respiratory system compliance. Rescue therapies for life threatening hypoxemia such as prone position and ECMO were necessary in four and two patients, respectively. Only two study-related adverse events were observed (intravascular hemolysis and femoral catheter kinking). The low-flow ECCOR system safely facilitates a low volume, low pressure ultra-protective mechanical ventilation strategy in patients with moderate ARDS.
| Idioma original | Inglés |
|---|---|
| Publicación | Critical Care |
| Volumen | 20 |
| N.º | 1 |
| DOI | |
| Estado | Publicada - 2016 |
Huella
Profundice en los temas de investigación de 'Feasibility and safety of low-flow extracorporeal carbon dioxide removal to facilitate ultra-protective ventilation in patients with moderate acute respiratory distress sindrome'. En conjunto forman una huella única.Citar esto
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver