Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Applying two approaches to detect unmeasured confounding due to time-varying variables in a self-controlled risk interval design evaluating COVID-19 vaccine safety signals, using myocarditis as a case example

Sophie H Bots, Svetlana Belitser, Rolf Groenwold, Carlos E Durán, Judit Riera-Arnau, Anna Schultze, Davide Messina, Elena Segundo, Ian Douglas, Juan José Carreras, Patricia Garcia-Poza, Rosa Gini, Consuelo Huerta, Mar Martín-Pérez, Ivonne Martin, Olga Paoletti, Carlo Alberto Bissacco, Elisa Correcher-Martínez, Patrick Souverein, Arantxa Urchueguía-FornesFelipe Villalobos, Miriam C J M Sturkenboom, Olaf H Klungel

Producción científica: Contribución a una revistaArtículoInvestigaciónrevisión exhaustiva

Resumen

We test the robustness of the self-controlled risk interval (SCRI) design in a setting where time between doses may introduce time-varying confounding, using both negative control outcomes (NCOs) and quantitative bias analysis (QBA). All vaccinated cases identified from 5 European databases between September 1, 2020, and end of data availability were included. Exposures were doses 1-3 of the Pfizer, Moderna, AstraZeneca, and Janssen COVID-19 vaccines; outcomes were myocarditis and, as the NCO, otitis externa. The SCRI used a 60-day control window and dose-specific 28-day risk windows, stratified by vaccine brand and adjusted for calendar time. The QBA included two scenarios: (1) baseline probability of the confounder was higher in the control window and (2) vice versa. The NCO was not associated with any of the COVID-19 vaccine types or doses except Moderna dose 1 (IRR = 1.09; 95% CI 1.01-1.09). The QBA suggested that even the strongest literature-reported confounder (COVID-19; RR for myocarditis = 18.3) could only explain away part of the observed effect, from IRR = 3 to IRR = 1.40. The SCRI seems robust to unmeasured confounding in the COVID-19 setting, although a strong unmeasured confounder could bias the observed effect upward. Replication of our findings for other safety signals would strengthen this conclusion. This article is part of a Special Collection on Pharmacoepidemiology.
Idioma originalInglés
Páginas (desde-hasta)208-219
Número de páginas12
PublicaciónAmerican Journal of Epidemiology
Volumen194
N.º1
DOI
EstadoPublicada - 2024

ODS de las Naciones Unidas

Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

  1. ODS 3: Salud y bienestar
    ODS 3: Salud y bienestar

Huella

Profundice en los temas de investigación de 'Applying two approaches to detect unmeasured confounding due to time-varying variables in a self-controlled risk interval design evaluating COVID-19 vaccine safety signals, using myocarditis as a case example'. En conjunto forman una huella única.

Citar esto