Accuracy of Y-function methods for parameters extraction of two-dimensional FETs across different technologies

Producción científica: Contribución a una revistaArtículoInvestigaciónrevisión exhaustiva

7 Citas (Scopus)

Resumen

The accuracy of contact resistance values of two-dimensional (2D) field-effect transistors extracted with the Y-function considering the impact of the intrinsic mobility degradation is evaluated here. The difference between methodologies that take this factor into account and ignore it is pointed out by a detailed analysis of the approximations of the transport model used for each extraction. In contrast to the oftenly used approach where the intrinsic mobility degradation is neglected, a Y-function-based method considering a more complete transport model yields contact resistance values similar to reference values obtained by other intricate approaches. The latter values are more suitable also to describe experimental data of 2D devices of different technologies. The intrinsic mobility degradation factor of 2D transistors is experimentally characterised for the first time and its impact on the device performance is described and evaluated.
Idioma originalInglés
Páginas (desde-hasta)942 – 945
Número de páginas4
PublicaciónElectronics Letters
Volumen56
N.º18
DOI
EstadoPublicada - 3 sept 2020

Huella

Profundice en los temas de investigación de 'Accuracy of Y-function methods for parameters extraction of two-dimensional FETs across different technologies'. En conjunto forman una huella única.

Citar esto