Use of electrical impedance tomography (EIT) for the assessment of unilateral pulmonary function

Roberto E. Serrano, Bruno De Lema, Oscar Casas, Teresa Feixas, Nuria Calaf, Valle Camacho, Ignasi Carrió, Pere Casan, J. Sanchis, Pere J. Riu

Research output: Contribution to journalArticleResearchpeer-review

38 Citations (Scopus)

Abstract

We describe a fully automatable quantification process for the assessment of unilateral pulmonary function (UPF) by means of EIT and propose a measurement protocol for its clinical implementation. Measurements were performed at the fourth and sixth intercostal levels on a first group of ten healthy subjects (5M, 5F, ages 26-48 years) to define the proper protocol by evaluating the most common postures and ventilation modes. Several off-line processing tools were also evaluated, including the use of digital filters to extract the respiratory components from EIT time series. Comparative measures were then carried out on a second group consisting of five preoperatory patients with lung cancer (4M, 1F, ages 25-77 years) scheduled for radionuclide scanning. Results show that measurements were best performed with the subject sitting down, holding his arms up and breathing spontaneously. As regards data processing, it is best to extract Fourier respiratory components. The mean of the healthy subject group leads to a left-right division of lung ventilation consistent with literature values (47% left lung, 53% right lung). The comparative study indicates a good correlation (r = 0.96) between the two techniques, with a mean difference of (-0.4 ± 5.4)%, suggesting that the elimination of cardiac components from the thoracic transimpedance signal leads to a better estimation of UPF.
Original languageEnglish
Pages (from-to)211-220
JournalPhysiological Measurement
Volume23
DOIs
Publication statusPublished - 27 Feb 2002

Keywords

  • Electrical impedance tomography
  • Lung function
  • Radionuclide scanning
  • Unilateral lung function
  • Ventilation

Fingerprint Dive into the research topics of 'Use of electrical impedance tomography (EIT) for the assessment of unilateral pulmonary function'. Together they form a unique fingerprint.

  • Cite this

    Serrano, R. E., De Lema, B., Casas, O., Feixas, T., Calaf, N., Camacho, V., Carrió, I., Casan, P., Sanchis, J., & Riu, P. J. (2002). Use of electrical impedance tomography (EIT) for the assessment of unilateral pulmonary function. Physiological Measurement, 23, 211-220. https://doi.org/10.1088/0967-3334/23/1/322