TY - JOUR
T1 - Use of a plasma focus device to study pulsed x-ray effects on peripheral blood lymphocytes: Analysis of chromosome aberrations
AU - Verdejo, Valentina
AU - Radl, Analía
AU - Barquinero, Joan-Francesc
AU - Jain, Jalaj
AU - Davis, Sergio
AU - Pavez, Cristian
AU - Soto, Leopoldo
AU - Moreno, José
PY - 2023/4/28
Y1 - 2023/4/28
N2 - X-ray pulses (full width at half maximum ∼ 90 ns, dose rate ∼ 107 Gy s−1) were used to irradiate the monolayer of peripheral blood mononucleated cells using the PF-2kJ kilojoule plasma focus device. Four different exposure conditions were evaluated using 5, 10, 20, and 40 pulses, with the mean dose measured by TLD-100 being 0.12 ± 0.02 mGy, 0.14 ± 0.03 mGy, 0.22 ± 0.06 mGy, and 0.47 ± 0.09 mGy, respectively. Cytogenetic analysis showed an increase in all types of chromosomal aberrations following exposure to x-ray pulses. The distribution of dicentrics and centric rings was overdispersed after 5, 10, 20, and 40 pulses. Additionally, after 20 and 40 pulses, the presence of tricentric chromosomes is detected. Chromosome aberration frequencies found in this study were always higher than the estimated frequencies of chromosome aberrations using published dose–effect curves for conventional radiation sources. The overdispersion observed, the elevated maximum relative biological effectiveness (RBEM) and the presence of tricentric chromosomes at the relatively low doses of exposure (
AB - X-ray pulses (full width at half maximum ∼ 90 ns, dose rate ∼ 107 Gy s−1) were used to irradiate the monolayer of peripheral blood mononucleated cells using the PF-2kJ kilojoule plasma focus device. Four different exposure conditions were evaluated using 5, 10, 20, and 40 pulses, with the mean dose measured by TLD-100 being 0.12 ± 0.02 mGy, 0.14 ± 0.03 mGy, 0.22 ± 0.06 mGy, and 0.47 ± 0.09 mGy, respectively. Cytogenetic analysis showed an increase in all types of chromosomal aberrations following exposure to x-ray pulses. The distribution of dicentrics and centric rings was overdispersed after 5, 10, 20, and 40 pulses. Additionally, after 20 and 40 pulses, the presence of tricentric chromosomes is detected. Chromosome aberration frequencies found in this study were always higher than the estimated frequencies of chromosome aberrations using published dose–effect curves for conventional radiation sources. The overdispersion observed, the elevated maximum relative biological effectiveness (RBEM) and the presence of tricentric chromosomes at the relatively low doses of exposure (
UR - https://doi.org/10.1063/5.0141529
M3 - Article
SN - 0021-8979
VL - 133
JO - Journal of Applied Physics
JF - Journal of Applied Physics
M1 - 163302
ER -