Respirometric assays at fixed and process temperatures to monitor composting process

Research output: Contribution to journalArticleResearchpeer-review

84 Citations (Scopus)

Abstract

A static respirometer was built to determine the respiration index (RI) of composting samples. Respiration indices of different sludges were determined at 37°C (RI37) and at the in situ temperature of the composter at sampling (RIT). Results indicated that both indices correlated well with temperature evolution in the composter. RIT were more representative of the metabolic activity in the reactor and more sensitive to temperature and composition variations of the composting material, but could not indicate the stability of the material at later stages of the process. Moreover, significance of RI units was shown in the composting of a highly compostable residue. According to the stability limits suggested in the literature, initial RI expressed on dry matter (DM) basis corresponds to a stable material (RI < 1 mg O2 g DM-1 h-1) whereas initial RI expressed on organic matter basis (OM) corresponds to an unstable material (RI = 2.5 mg O2 g OM-1 h-1). © 2004 Elsevier Ltd. All rights reserved.
Original languageEnglish
Pages (from-to)1153-1159
JournalBioresource Technology
Volume96
DOIs
Publication statusPublished - 1 Jul 2005

Keywords

  • Monitoring
  • Respiration index
  • Stability

Fingerprint Dive into the research topics of 'Respirometric assays at fixed and process temperatures to monitor composting process'. Together they form a unique fingerprint.

Cite this