Skip to main navigation Skip to search Skip to main content

Reliability of thromboelastometry for detecting the safe coagulation threshold in patients taking acenocoumarol after elective heart valve replacement

Annabel Blasi*, Guido Muñoz, Ines De Soto, Ricard Mellado, Pilar Taura, Jose Rios, Jaume Balust, Joan Beltran

*Corresponding author for this work

Research output: Contribution to journalArticleResearchpeer-review

Abstract

© 2015 Elsevier Ltd. Background Reversal of anticoagulation can be needed in patients undergoing heart valve surgery. ROTEM® has been correlated with international normalized ratio (INR) in patients on warfarin but not with patients on acenocoumarol. This study investigates the reliability of ROTEM® for detecting INR values below the 1.5 threshold in patients on acenocoumarol therapy. Material and methods Patients on oral anticoagulation with acenocoumarol after elective heart valve replacement were prospectively included in the study. INR and the ROTEM® were measured simultaneously. ROTEM® parameters included coagulation time, clot formation time, alpha angle, and maximal clot firmness after tissue factor activation (EXTEM). Concordance between INR and ROTEM® was analyzed by Lin's concordance coefficient (LCC) and the correlation with Spearman's rho. Results Fifty-four consecutive patients (40 female; median age 67 years) were included. Clotting time (CT) was the parameter that best correlated with INR (r = 0.81, p < 0,001), and LCC was substantial (0.67). CT was able to predict INR values above or below 1.5: area under curve = 0.998. CT ≥ 84 seconds, corresponding to a cut-off for likelihood ratio (LR +) = 5, had a sensitivity and specificity of 100% and 80%, respectively, to detect an INR below 1.5. For the same INR threshold, CT ≥ 84 seconds had a predictive positive value of 92.9% and a predictive negative value of 100%. Conclusion Our preliminary results suggest that CT ≥ 84 seconds in the EXTEM ROTEM® test is a feasible method for predicting an insufficient reversion of oral anticoagulant therapy in patients taking acenocoumarol after elective heart valve surgery.
Original languageEnglish
Pages (from-to)669-672
Number of pages4
JournalThrombosis Research
Volume136
Issue number3
DOIs
Publication statusPublished - 1 Sept 2015

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • acenocumarol
  • thromboelastometry

Fingerprint