Performance and limitations of noninvasive cardiac activation mapping

Josselin Duchateau*, Frédéric Sacher, Thomas Pambrun, Nicolas Derval, Judit Chamorro-Servent, Arnaud Denis, Sylvain Ploux, Mélèze Hocini, Pierre Jaïs, Olivier Bernus, Michel Haïssaguerre, Rémi Dubois

*Corresponding author for this work

Research output: Contribution to journalArticleResearchpeer-review

Abstract

Background: Activation mapping using noninvasive electrocardiographic imaging (ECGi) has recently been used to describe the physiology of different cardiac abnormalities. These descriptions differ from prior invasive studies, and both methods have not been thoroughly confronted in a clinical setting. Objective: The goal of the present study was to provide validation of noninvasive activation mapping in a clinical setting through direct confrontation with invasive epicardial contact measures. Methods: Fifty-nine maps were obtained in 55 patients and aligned on a common geometry. Nearest-neighbor interpolation was used to avoid map smoothing. Quantitative comparison was performed by computing between-map correlation coefficients and absolute activation time errors. Results: The mean activation time error was 20.4 ± 8.6 ms, and the between-map correlation was poor (0.03 ± 0.43). The results suggested high interpatient variability (correlation −0.68 to 0.82), wide QRS patterns, and paced rhythms demonstrating significantly better mean correlation (0.68 ± 0.17). Errors were greater in scarred regions (21.9 ± 10.8 ms vs 17.5 ± 6.7 ms; P <.01). Fewer epicardial breakthroughs were imaged using noninvasive mapping (1.3 ± 0.5 vs 2.3 ± 0.7; P <.01). Primary breakthrough locations were imaged 75.7 ± 38.1 mm apart. Lines of conduction block (jumps of ≥50 ms between contiguous points) due to structural anomalies were recorded in 27 of 59 contact maps and were not visualized at these same sites noninvasively. Instead, artificial lines appeared in 33 of 59 noninvasive maps in regions of reduced bipolar voltage amplitudes (P =.03). An in silico model confirms these artificial constructs. Conclusion: Overall, agreement of ECGi activation mapping and contact mapping is poor and heterogeneous. The between-map correlation is good for wide QRS patterns. Lines of block and epicardial breakthrough sites imaged using ECGi are inaccurate. Further work is required to improve the accuracy of the technique.

Original languageEnglish
Pages (from-to)435-442
Number of pages8
JournalHeart Rhythm
Volume16
Issue number3
DOIs
Publication statusPublished - Mar 2019

Keywords

  • Breakthrough
  • Conduction block
  • Electrocardiography
  • Electrophysiology
  • Imaging
  • Mapping
  • Noninvasive mapping

Fingerprint

Dive into the research topics of 'Performance and limitations of noninvasive cardiac activation mapping'. Together they form a unique fingerprint.

Cite this