T1 - Optimization and calibration of a polarization-camera-based Mueller imaging polarimeter for biological samples examination
AU - Gonzalez, Ivan Montes
AU - Eeckhout, Albert Van
AU - Estévez, Irene
AU - Canabal-Carbia, Mónica
AU - Lizana, Ángel
AU - Campos, Juan
N1 - Publisher Copyright:
© 2024 SPIE.
PY - 2024/3/12
Y1 - 2024/3/12
N2 - We present the optimization and calibration of a Mueller matrix imaging polarimeter. The polarimeter is intended to be used as a compact tool for biomedical diagnosis, in particular for skin examination. The device uses a pixelated-polarization camera along with a fixed variable retarder for the polarization state analyzer, minimizing the number of elements used in the device for Full-Mueller matrix measurements. For the polarization state generator the device uses an LED as light source, and a polarizer followed by a pair of LCVRs to generate any polarization state over the Poincare sphere. With this system the polarization properties of a sample can be obtained with a total of 8 measurements to extract the 16 elements of the Mueller matrix. We study the optimization strategies by minimizing the condition number of the instrument matrix, to maximize the signal to noise ratio, and reducing the effect of experimental errors on the optimization. As a compact and transportable tool, the polarimeter will be used in different environments, so an auto-calibration method is also required. In this work we explore the necessary conditions to successfully use the Eigenvalue calibration method in a polarized-camera and liquid crystals based polarimeter. The study presented will help to measure the Mueller matrix of a sample with high accuracy and precision levels, needed for the study of biological samples
AB - We present the optimization and calibration of a Mueller matrix imaging polarimeter. The polarimeter is intended to be used as a compact tool for biomedical diagnosis, in particular for skin examination. The device uses a pixelated-polarization camera along with a fixed variable retarder for the polarization state analyzer, minimizing the number of elements used in the device for Full-Mueller matrix measurements. For the polarization state generator the device uses an LED as light source, and a polarizer followed by a pair of LCVRs to generate any polarization state over the Poincare sphere. With this system the polarization properties of a sample can be obtained with a total of 8 measurements to extract the 16 elements of the Mueller matrix. We study the optimization strategies by minimizing the condition number of the instrument matrix, to maximize the signal to noise ratio, and reducing the effect of experimental errors on the optimization. As a compact and transportable tool, the polarimeter will be used in different environments, so an auto-calibration method is also required. In this work we explore the necessary conditions to successfully use the Eigenvalue calibration method in a polarized-camera and liquid crystals based polarimeter. The study presented will help to measure the Mueller matrix of a sample with high accuracy and precision levels, needed for the study of biological samples
KW - Mueller matrix
KW - Polarimetry
KW - imaging
KW - liquid crystals
UR - http://www.scopus.com/inward/record.url?scp=85194412911&partnerID=8YFLogxK
U2 - 10.1117/12.3001536
DO - 10.1117/12.3001536
M3 - Article
VL - 12845
JO - Proc. SPIE
JF - Proc. SPIE
M1 - 1284507
ER -