TY - JOUR
T1 - Ion mobility spectrometry for the simultaneous determination of diacetyl midecamycin and detergents in cleaning validation
AU - Armenta, S.
AU - Alcalà, M.
AU - Blanco, M.
AU - González, J. M.
PY - 2013/9/1
Y1 - 2013/9/1
N2 - In the present paper, we have developed two different approaches based on ion mobility spectrometry (IMS) for the cleaning validation of diacetyl midecamycin in the surfaces of manufacture equipment: a semi-quantitative approach based on the use of a sample wand and a quantitative procedure based on the swab test. The simultaneous determination of the active pharmaceutical ingredient and cleaning agents has been performed without important effects of ionization suppression upon the analysis of swabs containing multiple components. Sensitivity, in the ng range, and appropriate selectivity ratify IMS as a serious alternative, a fast and serious alternative in cleaning validation. Other advantage imply its potential for at-line use to perform a semi-quantitative procedure using a sample wand which allows Teflon membranes, swabbed onto the stainless steel surfaces, to be introduced directly into the instrument with no dilution or extraction. © 2013 Elsevier B.V.
AB - In the present paper, we have developed two different approaches based on ion mobility spectrometry (IMS) for the cleaning validation of diacetyl midecamycin in the surfaces of manufacture equipment: a semi-quantitative approach based on the use of a sample wand and a quantitative procedure based on the swab test. The simultaneous determination of the active pharmaceutical ingredient and cleaning agents has been performed without important effects of ionization suppression upon the analysis of swabs containing multiple components. Sensitivity, in the ng range, and appropriate selectivity ratify IMS as a serious alternative, a fast and serious alternative in cleaning validation. Other advantage imply its potential for at-line use to perform a semi-quantitative procedure using a sample wand which allows Teflon membranes, swabbed onto the stainless steel surfaces, to be introduced directly into the instrument with no dilution or extraction. © 2013 Elsevier B.V.
KW - Cleaning agents
KW - Cleaning validation
KW - Diacetyl midecamycin
KW - Ion mobility spectrometry
KW - Pharmaceuticals
U2 - 10.1016/j.jpba.2013.05.016
DO - 10.1016/j.jpba.2013.05.016
M3 - Article
SN - 0731-7085
VL - 83
SP - 265
EP - 272
JO - Journal of Pharmaceutical and Biomedical Analysis
JF - Journal of Pharmaceutical and Biomedical Analysis
ER -