High-throughput real-time reverse transcription-PCR quantitation of hepatitis C virus RNA

María Martell, Jordi Gómez, Juan I. Esteban*, Silvia Sauleda, Josep Quer, Beatriz Cabot, Rafael Esteban, Jaime Guardia

*Corresponding author for this work

Research output: Contribution to journalArticleResearchpeer-review

211 Citations (Scopus)

Abstract

We describe a rapid and reproducible method for assessment of the hepatitis C virus (HCV) load in serum samples. The method combines Taqman technology (Roche) and the ABI Prism 7700 (Perkin Elmer) real-time sequence detection system. We have optimized a single-tube reverse transcription-PCR (RT-PCR) that contains a dual-labeled fluorogenic probe to quantify the 5' noncoding region (5' NCR) of HCV. The probe contains a fluorescent reporter at the 5' end and a fluorescent quencher at the 3' end. The use of such a probe combined with the 5'-3' nuclease activity of Taq polymerase allows direct quantitation of the PCR product by the detection of a fluorescent reporter released in the course of the exponential phase of the PCR. For accurate quantitation of the number of copies of HCV in samples containing unknown quantities, we have used serial dilutions of a synthetic 5' NCR RNA standard of HCV that was previously quantified with an isotopic tracer. The method has a 5-log dynamic range (103 to 107). The coefficient of regression of the standard curve was, on average, 0.98. The intra-assay and the interassay coefficients of variation of the threshold cycle were 1% and 6.2%, respectively. Seventy-nine RNA samples from the sera of infected patients were quantified by this method. Comparison of the results with those obtained by other quantitation methods (the Quantiplex 2.0 branched-DNA assay and the Superquant assay from the National Genetics Institute) revealed a significant correlation with all of the results. The mean values were also statistically comparable. In conclusion, the high sensitivity, simplicity, and reproducibility of the real-time HCV RNA quantitation which allows the screening of large numbers of samples, combined with its wide dynamic range, make this method especially suitable for monitoring of the viral load during therapy and tailoring of treatment schedules.

Original languageEnglish
Pages (from-to)327-332
Number of pages6
JournalJournal of Clinical Microbiology
Volume37
Issue number2
DOIs
Publication statusPublished - 1 Feb 1999

Fingerprint

Dive into the research topics of 'High-throughput real-time reverse transcription-PCR quantitation of hepatitis C virus RNA'. Together they form a unique fingerprint.

Cite this