Development of a univariate calibration model for pharmaceutical analysis based on NIR spectra

M. Blanco, J. Cruz, M. Bautista

Research output: Contribution to journalArticleResearchpeer-review

26 Citations (Scopus)

Abstract

Near-infrared spectroscopy (NIRS) has been widely used in the pharmaceutical field because of its ability to provide quality information about drugs in near-real time. In practice, however, the NIRS technique requires construction of multivariate models in order to correct collinearity and the typically poor selectivity of NIR spectra. In this work, a new methodology for constructing simple NIR calibration models has been developed, based on the spectrum for the target analyte (usually the active principle ingredient, API), which is compared with that of the sample in order to calculate a correlation coefficient. To this end, calibration samples are prepared spanning an adequate concentration range for the API and their spectra are recorded. The model thus obtained by relating the correlation coefficient to the sample concentration is subjected to least-squares regression. The API concentration in validation samples is predicted by interpolating their correlation coefficients in the straight calibration line previously obtained. The proposed method affords quantitation of API in pharmaceuticals undergoing physical changes during their production process (e.g. granulates, and coated and non-coated tablets). The results obtained with the proposed methodology, based on correlation coefficients, were compared with the predictions of PLS1 calibration models, with which a different model is required for each type of sample. Error values lower than 1-2% were obtained in the analysis of three types of sample using the same model; these errors are similar to those obtained by applying three PLS models for granules, and non-coated and coated samples. Based on the outcome, our methodology is a straightforward choice for constructing calibration models affording expeditious prediction of new samples with varying physical properties. This makes it an effective alternative to multivariate calibration, which requires use of a different model for each type of sample, depending on its physical presentation. © 2008 Springer-Verlag.
Original languageEnglish
Pages (from-to)1367-1372
JournalAnalytical and Bioanalytical Chemistry
Volume392
Issue number7-8
DOIs
Publication statusPublished - 1 Dec 2008

Keywords

  • API determination
  • Correlation coefficients
  • NIR spectroscopy
  • PLS calibration

Fingerprint Dive into the research topics of 'Development of a univariate calibration model for pharmaceutical analysis based on NIR spectra'. Together they form a unique fingerprint.

Cite this