T1 - Construction and validation of a dose-response curve using the comet assay to determine human radiosensitivity to ionizing radiation
AU - Guerci, A.
AU - Zuniga, L.
AU - Marcos, R.
PY - 2011/8/1
Y1 - 2011/8/1
N2 - Individual radiosensitivity is an individual characteristic associated with an increased reaction to ionizing radiation. The purpose of our work is to establish a dose-response curve useful to classify individuals as radiosensitive or radioresistant. Thus, a dose-response curve was constructed by measuring in vitro responses to increasing doses (0 to 8 Gy) of gamma radiation in the comet assay. The obtained curve fit well with a linear equation in the range of 0 to 8 Gy. The overall dose-response curve was constructed for percent DNA in tail, as a measure of the genetic damage induced by irradiation. To probe the goodness of the constructed curve, a validation study was carried out with whole blood from two donors in a blind study. Results show that, for the two applied doses (2 and 6 Gy), the obtained values fit well inside the interval of confidence of the curve. In conclusion, our results demonstrate the usefulness of the comet assay in determining individual responses to defined doses of gamma radiation. The standard dose-response curve constructed may be used to detect individuals departing from reference values. Copyright © Taylor & Francis Group, LLC.
AB - Individual radiosensitivity is an individual characteristic associated with an increased reaction to ionizing radiation. The purpose of our work is to establish a dose-response curve useful to classify individuals as radiosensitive or radioresistant. Thus, a dose-response curve was constructed by measuring in vitro responses to increasing doses (0 to 8 Gy) of gamma radiation in the comet assay. The obtained curve fit well with a linear equation in the range of 0 to 8 Gy. The overall dose-response curve was constructed for percent DNA in tail, as a measure of the genetic damage induced by irradiation. To probe the goodness of the constructed curve, a validation study was carried out with whole blood from two donors in a blind study. Results show that, for the two applied doses (2 and 6 Gy), the obtained values fit well inside the interval of confidence of the curve. In conclusion, our results demonstrate the usefulness of the comet assay in determining individual responses to defined doses of gamma radiation. The standard dose-response curve constructed may be used to detect individuals departing from reference values. Copyright © Taylor & Francis Group, LLC.
U2 - https://doi.org/10.1080/15287394.2011.582318
DO - https://doi.org/10.1080/15287394.2011.582318
M3 - Article
VL - 74
SP - 1087
EP - 1093
JO - Journal of Toxicology and Environmental Health - Part A: Current Issues
JF - Journal of Toxicology and Environmental Health - Part A: Current Issues
SN - 1528-7394
ER -