T1 - Comparative study of two different modes of noninvasive home mechanical ventilation in chronic respiratory failure
AU - Muñoz, Xavier
AU - Crespo, Astrid
AU - Marti, Sergi
AU - Torres, Ferran
AU - Ferrer, Jaume
AU - Morell, Ferran
PY - 2006/4/1
Y1 - 2006/4/1
N2 - Study objective: Two modes of noninvasive home mechanical ventilation (NIHMV) with volumetric ventilators were compared in patients with chronic respiratory failure. Design: Retrospective, parallel-group, comparative study. Setting: Third-level teaching Hospital in Barcelona (Spain). Patients and methods: We studied 110 patients with chronic hypercapnic respiratory failure secondary to neuromuscular disease, kyphoscoliosis or post-tuberculosis sequelae, starting NIHMV with volumetric ventilators. The assist/control (A/C) ventilation mode was used in 45 patients and the control (C) mode in 65 patients. Clinical characteristics, pulmonary function results and arterial blood gas findings were assessed in each patient before establishing ventilation and at 6 and 12 months after. The patient's satisfaction with ventilation, the time required for adaptation, and compliance with the prescription were also assessed. Measurements and results: Significant improvements in PaO2 and PaCO2 (P < 0.001) were found at 6 and 12 months with both modes of mechanical ventilation. There were no significant differences between the two modes for pulmonary function or blood gas parameters with the exception of maximum inspiratory pressure (MIP) in patients receiving the C mode, which was significantly different as compared to the baseline value after 12 months of use (mean± SD: 36.6±14.8 and 44.7±24.2 cmH2O, respectively; P = 0.010). No significant differences were found in adaptation, compliance with ventilation or patient satisfaction between the two modes studied. Conclusions: According to several factors analysed, results with the A/C or C mode used with volumetric ventilators appear to be comparable in patients with chronic respiratory disease receiving NIHMV. Choice of mode will depend on the acquired experience of the prescribing physicians in each centre. © 2005 Elsevier Ltd. All rights reserved.
AB - Study objective: Two modes of noninvasive home mechanical ventilation (NIHMV) with volumetric ventilators were compared in patients with chronic respiratory failure. Design: Retrospective, parallel-group, comparative study. Setting: Third-level teaching Hospital in Barcelona (Spain). Patients and methods: We studied 110 patients with chronic hypercapnic respiratory failure secondary to neuromuscular disease, kyphoscoliosis or post-tuberculosis sequelae, starting NIHMV with volumetric ventilators. The assist/control (A/C) ventilation mode was used in 45 patients and the control (C) mode in 65 patients. Clinical characteristics, pulmonary function results and arterial blood gas findings were assessed in each patient before establishing ventilation and at 6 and 12 months after. The patient's satisfaction with ventilation, the time required for adaptation, and compliance with the prescription were also assessed. Measurements and results: Significant improvements in PaO2 and PaCO2 (P < 0.001) were found at 6 and 12 months with both modes of mechanical ventilation. There were no significant differences between the two modes for pulmonary function or blood gas parameters with the exception of maximum inspiratory pressure (MIP) in patients receiving the C mode, which was significantly different as compared to the baseline value after 12 months of use (mean± SD: 36.6±14.8 and 44.7±24.2 cmH2O, respectively; P = 0.010). No significant differences were found in adaptation, compliance with ventilation or patient satisfaction between the two modes studied. Conclusions: According to several factors analysed, results with the A/C or C mode used with volumetric ventilators appear to be comparable in patients with chronic respiratory disease receiving NIHMV. Choice of mode will depend on the acquired experience of the prescribing physicians in each centre. © 2005 Elsevier Ltd. All rights reserved.
KW - Chronic respiratory failure
KW - NIHMV
KW - Ventilation mode
KW - Volumetric ventilators
U2 - 10.1016/j.rmed.2005.08.008
DO - 10.1016/j.rmed.2005.08.008
M3 - Article
VL - 100
SP - 673
EP - 681
JO - Respiratory Medicine
JF - Respiratory Medicine
SN - 0954-6111
IS - 4
ER -