Antiseptic chamber-containing hub reduces central venous catheter-related infection: A prospective, randomized study

Cristóbal León, Francisco Álvarez-Lerma, Sergio Ruiz-Santana, Víctor González, María Victoria De La Torre, Rafael Sierra, Miguel León, Juan José Rodrigo

Research output: Contribution to journalArticleResearchpeer-review

37 Citations (Scopus)

Abstract

Objective: The hub connecting the catheter and the infusion equipment is a common portal of entry for bacteria causing catheter-related sepsis. We assessed the efficacy of a new hub model (Segur-Lock) that incorporates an antiseptic chamber filled with 3% iodinated alcohol in preventing endoluminal catheter contamination and catheter-related bloodstream infection arising at the hub. Design: Prospective, randomized, multicenter study. Setting: Seven medical and surgical adult intensive care units in Spain. Patients: A total of 230 patients aged 18 yrs or older requiring the insertion of a nontunneled central venous catheter for ≥6 days from January 1, 1998, to April 30, 1999. Interventions: Patients were randomized at the time of catheter insertion to receive catheters with standard Luer-lock connector (control group, n = 114) or catheters with the new hub model (n = 116). Measurements and Main Results: Skin, catheter tip, and hub cultures were performed at the time the catheter was withdrawn because therapy was terminated or due to suspicion of sepsis, in which case peripheral blood and infusate cultures were simultaneously taken. Catheter-related bloodstream infection was diagnosed in 19 (8.3%) patients. Catheters were more often withdrawn because of suspicion of infection in the control group (43.8%) than in the new hub model group (30.1%, p < .035). The prevalence of culture-positive catheter hubs without associated bacteremia (colonization) was higher in the control group (14.4% vs. 4.3%, p < .001). Catheter-relatod bloodstream infection from the catheter hub also occurred more frequently in controls than in patients assigned to the new hub model (7% vs. 1.7%; p < .049; relative risk, 4.14; 95% confidence interval, 0.8-19). Conclusions: This new antiseptic chamber-containing hub has proved to be effective in preventing endoluminal bacterial colonization and catheter-related bloodstream infection from hub contamination in intensive care unit patients with central venous catheters inserted for ≥6 days.
Original languageEnglish
Pages (from-to)1318-1324
JournalCritical Care Medicine
Volume31
Issue number5
DOIs
Publication statusPublished - 1 May 2003

Keywords

  • Catheter hub
  • Catheter-related bloodstream infection
  • Catheterization
  • Critical care
  • Cross-infection
  • Intensive care unit
  • Intravenous
  • Prevention

Fingerprint Dive into the research topics of 'Antiseptic chamber-containing hub reduces central venous catheter-related infection: A prospective, randomized study'. Together they form a unique fingerprint.