TY - JOUR
T1 - Signal enhancement in antibody microarrays using quantum dots nanocrystals: Application to potential Alzheimer's disease biomarker screening
AU - Morales-Narváez, Eden
AU - Montón, Helena
AU - Fomicheva, Anna
AU - Merkoçi, Arben
PY - 2012/8/7
Y1 - 2012/8/7
N2 - The performance of cadmium-selenide/zinc-sulfide (CdSe@ZnS) quantum dots (QDs) and the fluorescent dye Alexa 647 as reporter in an assay designed to detect apolipoprotein E (ApoE) has been compared. The assay is a sandwich immunocomplex microarray that functions via excitation by visible light. ApoE was chosen for its potential as a biomarker for Alzheimer's disease. The two versions of the microarray (QD or Alexa 647) were assessed under the same experimental conditions and then compared to a conventional enzyme-linked immunosorbent assay (ELISA) targeting ApoE. The QDs proved to be highly effective reporters in the microarrays, although their performance strongly varied in function of the excitation wavelength. At 633 nm, the QD microarray gave a limit of detection (LOD) of ∼247 pg mL-1; however, at an excitation wavelength of 532 nm, it provided a LOD of ∼62 pg mL -1, five times more sensitive than that of the Alexa microarray (∼307 pg mL-1) and seven times more than that of the ELISA (∼470 pg mL-1). Finally, serial dilutions from a human serum sample were assayed with high sensitivity and acceptable precision and accuracy. © 2012 American Chemical Society.
AB - The performance of cadmium-selenide/zinc-sulfide (CdSe@ZnS) quantum dots (QDs) and the fluorescent dye Alexa 647 as reporter in an assay designed to detect apolipoprotein E (ApoE) has been compared. The assay is a sandwich immunocomplex microarray that functions via excitation by visible light. ApoE was chosen for its potential as a biomarker for Alzheimer's disease. The two versions of the microarray (QD or Alexa 647) were assessed under the same experimental conditions and then compared to a conventional enzyme-linked immunosorbent assay (ELISA) targeting ApoE. The QDs proved to be highly effective reporters in the microarrays, although their performance strongly varied in function of the excitation wavelength. At 633 nm, the QD microarray gave a limit of detection (LOD) of ∼247 pg mL-1; however, at an excitation wavelength of 532 nm, it provided a LOD of ∼62 pg mL -1, five times more sensitive than that of the Alexa microarray (∼307 pg mL-1) and seven times more than that of the ELISA (∼470 pg mL-1). Finally, serial dilutions from a human serum sample were assayed with high sensitivity and acceptable precision and accuracy. © 2012 American Chemical Society.
UR - https://www.scopus.com/pages/publications/84864582026
U2 - 10.1021/ac301369e
DO - 10.1021/ac301369e
M3 - Article
SN - 0003-2700
VL - 84
SP - 6821
EP - 6827
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 15
ER -