TY - JOUR
T1 - Predictors of acute failure ablation of intra-atrial re-entrant tachycardia in patients with congenital heart disease
T2 - Cardiac disease, atypical flutter, and previous atrial fibrillation
AU - Roca-Luque, Ivo
AU - Rivas-Gándara, Nuria
AU - Dos-Subirá, Laura
AU - Francisco-Pascual, Jaume
AU - Pijuan-Domenech, Antónia
AU - Pérez-Rodon, Jordi
AU - Santos-Ortega, Alba
AU - Roses-Noguer, Ferran
AU - Ferreira-Gonzalez, Ignacio
AU - García, David García Dorado
AU - Mitjans, Angel Moya
N1 - Publisher Copyright:
© 2018 The Authors.
PY - 2018/4/1
Y1 - 2018/4/1
N2 - Background--Intra-atrial re-entrant tachycardia (IART) in patients with congenital heart disease (CHD) increases morbidity and mortality. Radiofrequency catheter ablation has evolved as the first-line treatment. The aim of this study was to analyze the acute success and to identify predictors of failed IART radiofrequency catheter ablation in CHD. Methods and Results--The observational study included all consecutive patients with CHD who underwent a first ablation procedure for IART at a single center from January 2009 to December 2015 (94 patients, 39.4% female, age: 36.55±14.9 years). In the first procedure, 114 IART were ablated (acute success: 74.6%; 1.21±0.41 IART per patient) with an acute success of 74.5%. Cavotricuspid isthmus-related IART was the only arrhythmia in 51%; non-cavotricuspid isthmus-related IART was the only mechanism in 27.7% and 21.3% of the patients had both types of IART. Predictors of acute radiofrequency catheter ablation failure were as follows: nonrelated cavotricuspid isthmus IART (odds ratio 7.3; confidence interval [CI], 1.9-17.9; P=0.04), previous atrial fibrillation (odds ratio 6.1; CI, 1.3-18.4; P=0.02), transposition of great arteries (odds ratio, 4.9; CI, 1.4-17.2; P=0.01) and systemic ventricle dilation (odds ratio 4.8; CI, 1.1-21.7; P=0.04) with an area under the receiver operating characteristic curve of 0.83±0.056 (CI, 0.74-0.93, P=0.001). After a mean follow-up longer than 3.5 years, 78.3% of the patients were in sinus rhythm (33.1% of the patients required more than 1 radiofrequency catheter ablation procedure). Conclusions--Although ablation in CHD is a challenging procedure, acute success of 75% can be achieved in moderate-highly complex CHD patients in a referral center. Predictors of failed ablation are IART different from cavotricuspid isthmus, previous atrial fibrillation, and markers of complex CHD (transposition of great arteries, systemic ventricle dilation).
AB - Background--Intra-atrial re-entrant tachycardia (IART) in patients with congenital heart disease (CHD) increases morbidity and mortality. Radiofrequency catheter ablation has evolved as the first-line treatment. The aim of this study was to analyze the acute success and to identify predictors of failed IART radiofrequency catheter ablation in CHD. Methods and Results--The observational study included all consecutive patients with CHD who underwent a first ablation procedure for IART at a single center from January 2009 to December 2015 (94 patients, 39.4% female, age: 36.55±14.9 years). In the first procedure, 114 IART were ablated (acute success: 74.6%; 1.21±0.41 IART per patient) with an acute success of 74.5%. Cavotricuspid isthmus-related IART was the only arrhythmia in 51%; non-cavotricuspid isthmus-related IART was the only mechanism in 27.7% and 21.3% of the patients had both types of IART. Predictors of acute radiofrequency catheter ablation failure were as follows: nonrelated cavotricuspid isthmus IART (odds ratio 7.3; confidence interval [CI], 1.9-17.9; P=0.04), previous atrial fibrillation (odds ratio 6.1; CI, 1.3-18.4; P=0.02), transposition of great arteries (odds ratio, 4.9; CI, 1.4-17.2; P=0.01) and systemic ventricle dilation (odds ratio 4.8; CI, 1.1-21.7; P=0.04) with an area under the receiver operating characteristic curve of 0.83±0.056 (CI, 0.74-0.93, P=0.001). After a mean follow-up longer than 3.5 years, 78.3% of the patients were in sinus rhythm (33.1% of the patients required more than 1 radiofrequency catheter ablation procedure). Conclusions--Although ablation in CHD is a challenging procedure, acute success of 75% can be achieved in moderate-highly complex CHD patients in a referral center. Predictors of failed ablation are IART different from cavotricuspid isthmus, previous atrial fibrillation, and markers of complex CHD (transposition of great arteries, systemic ventricle dilation).
KW - Ablation
KW - Congenital heart disease
KW - Flutter
KW - Ablation
KW - Congenital heart disease
KW - Flutter
KW - Ablation
KW - Congenital heart disease
KW - Flutter
UR - http://www.scopus.com/inward/record.url?scp=85044864800&partnerID=8YFLogxK
U2 - 10.1161/JAHA.117.008063
DO - 10.1161/JAHA.117.008063
M3 - Article
C2 - 29602766
AN - SCOPUS:85044864800
SN - 2047-9980
VL - 7
JO - Journal of the American Heart Association
JF - Journal of the American Heart Association
IS - 7
M1 - e008063
ER -