Performance and limitations of noninvasive cardiac activation mapping

Josselin Duchateau*, Frédéric Sacher, Thomas Pambrun, Nicolas Derval, Judit Chamorro-Servent, Arnaud Denis, Sylvain Ploux, Mélèze Hocini, Pierre Jaïs, Olivier Bernus, Michel Haïssaguerre, Rémi Dubois

*Autor corresponent d’aquest treball

Producció científica: Contribució a revistaArticleRecercaAvaluat per experts

125 Cites (Scopus)

Resum

Background: Activation mapping using noninvasive electrocardiographic imaging (ECGi) has recently been used to describe the physiology of different cardiac abnormalities. These descriptions differ from prior invasive studies, and both methods have not been thoroughly confronted in a clinical setting. Objective: The goal of the present study was to provide validation of noninvasive activation mapping in a clinical setting through direct confrontation with invasive epicardial contact measures. Methods: Fifty-nine maps were obtained in 55 patients and aligned on a common geometry. Nearest-neighbor interpolation was used to avoid map smoothing. Quantitative comparison was performed by computing between-map correlation coefficients and absolute activation time errors. Results: The mean activation time error was 20.4 ± 8.6 ms, and the between-map correlation was poor (0.03 ± 0.43). The results suggested high interpatient variability (correlation −0.68 to 0.82), wide QRS patterns, and paced rhythms demonstrating significantly better mean correlation (0.68 ± 0.17). Errors were greater in scarred regions (21.9 ± 10.8 ms vs 17.5 ± 6.7 ms; P <.01). Fewer epicardial breakthroughs were imaged using noninvasive mapping (1.3 ± 0.5 vs 2.3 ± 0.7; P <.01). Primary breakthrough locations were imaged 75.7 ± 38.1 mm apart. Lines of conduction block (jumps of ≥50 ms between contiguous points) due to structural anomalies were recorded in 27 of 59 contact maps and were not visualized at these same sites noninvasively. Instead, artificial lines appeared in 33 of 59 noninvasive maps in regions of reduced bipolar voltage amplitudes (P =.03). An in silico model confirms these artificial constructs. Conclusion: Overall, agreement of ECGi activation mapping and contact mapping is poor and heterogeneous. The between-map correlation is good for wide QRS patterns. Lines of block and epicardial breakthrough sites imaged using ECGi are inaccurate. Further work is required to improve the accuracy of the technique.

Idioma originalAnglès
Pàgines (de-a)435-442
Nombre de pàgines8
RevistaHeart Rhythm
Volum16
Número3
DOIs
Estat de la publicacióPublicada - de març 2019

Fingerprint

Navegar pels temes de recerca de 'Performance and limitations of noninvasive cardiac activation mapping'. Junts formen un fingerprint únic.

Com citar-ho