TY - JOUR
T1 - Neutron dosimetry inside the containment building of Spanish nuclear power plants with PADC based dosemeters
AU - García-Fusté, M. J.
AU - Domingo, C.
AU - Amgarou, K.
AU - Bouassoule, T.
AU - Castelo, J.
N1 - Funding Information:
This work has been funded by the CSN with the support of the Spanish Nuclear Power Plants Association (UNESA) under contract PR-15. The authors wish to thank the staff at Ascó I nuclear power plant for their valuable work and help in setting up and performing all the experiments involved in this work.
PY - 2009/10
Y1 - 2009/10
N2 - The Spanish Nuclear Safety Council (Consejo de Seguridad Nuclear, CSN) recommends performing neutron individual dose assignments at workplaces based on ambient dose equivalent measurements using area monitors and by estimating the amount of time that workers spend in the different monitored environments. In addition, some Spanish nuclear power plants estimate the neutron dose equivalent using albedo thermoluminescence dosemeters (TLD). In the period 2004-2006, our group, together with other research centers, participated in a project, funded by the CSN, with the support of the Spanish Nuclear Power Plants Association (UNESA), to investigate in situ which could be the best practical procedure for individual neutron dose monitoring in nuclear power plants. As part of this survey, several units of the UAB PADC based neutron dosemeter were exposed, on a methacrylate phantom simulating a human body, at four different places inside the containment building of the Ascó I nuclear power plant. The influence of different types of calibration neutron fields is analysed and the dose equivalent for each point is estimated.
AB - The Spanish Nuclear Safety Council (Consejo de Seguridad Nuclear, CSN) recommends performing neutron individual dose assignments at workplaces based on ambient dose equivalent measurements using area monitors and by estimating the amount of time that workers spend in the different monitored environments. In addition, some Spanish nuclear power plants estimate the neutron dose equivalent using albedo thermoluminescence dosemeters (TLD). In the period 2004-2006, our group, together with other research centers, participated in a project, funded by the CSN, with the support of the Spanish Nuclear Power Plants Association (UNESA), to investigate in situ which could be the best practical procedure for individual neutron dose monitoring in nuclear power plants. As part of this survey, several units of the UAB PADC based neutron dosemeter were exposed, on a methacrylate phantom simulating a human body, at four different places inside the containment building of the Ascó I nuclear power plant. The influence of different types of calibration neutron fields is analysed and the dose equivalent for each point is estimated.
KW - Calibration factor
KW - Neutron dosimetry in nuclear power plants
KW - Neutron energy response
KW - PADC dosimeters
UR - http://www.scopus.com/inward/record.url?scp=70949089649&partnerID=8YFLogxK
U2 - 10.1016/j.radmeas.2009.10.078
DO - 10.1016/j.radmeas.2009.10.078
M3 - Article
AN - SCOPUS:70949089649
SN - 1350-4487
VL - 44
SP - 999
EP - 1001
JO - Radiation Measurements
JF - Radiation Measurements
IS - 9-10
ER -