Methanol determination in Pichia pastoris cultures by flow injection analysis

C. Almuzara, O. Cos, M. Baeza, D. Gabriel, F. Valero

Producció científica: Contribució a revistaArticleRecercaAvaluat per experts

18 Cites (Scopus)

Resum

An automated reverse flow injection analysis (r-FIA) system using stop-flow technique for quantifying methanol based on the enzymatic reactions of alcohol oxidase and peroxidase was developed. The system permitted methanol analysis in a linear range of 0.006-0.1 g methanol 1-1 without external dilution, and with a sampling frequency of 12 analyses per hour, with a relative standard deviation of 1.16%. The analyser was validated analysing samples from a Pichia pastoris fermentation producing a heterologous protein.