TY - JOUR
T1 - Lead(II) ion selective electrodes with PVC membranes based on two bis-thioureas as ionophores: 1,3-bis(N'-benzoylthioureido)benzene and 1,3-bis(N'-furoylthioureido)benzene
AU - Wilson, Deivy
AU - de los Ángeles Arada, María
AU - Alegret, Salvador
AU - del Valle, Manel
PY - 2010/9/1
Y1 - 2010/9/1
N2 - Two PVC membrane ion selective electrodes for Pb(II) ion based on two bis-thioureas: 1,3-bis(N'-benzoylthioureido)benzene and 1,3-bis(N'-furoylthioureido)benzene as ionophores, are reported. A first membrane formulated using 1,3-bis(N'-benzoylthioureido)benzene as carrier exhibited a Nernstian response to Pb(II) over a wide concentration range (4.0×10 -6 to 1.0×10 -2 M) with a slope of 31.5±1.6mV/dec. It showed a fast response time (t 90% =14s) and could be used for 10 weeks without any divergence in potentials. The membrane formulated using 1,3-bis(N'-furoylthioureido)benzene as carrier exhibited a Nernstian response in the concentration range (5.0×10 -6 to 1.0×10 -2 M), with a slope of 30.0±1.3mV/dec. Its response time was t 90% =14s, and it could be used for 14 weeks without any divergence in potentials. The two proposed potentiometric sensors revealed acceptable selectivities for Pb(II) over a wide variety of other metal ions and could be used in a pH range of 2.2-6.0. Both electrodes were assayed in direct potentiometric determination of lead in soils (10-30mg/kg range) with very good performance (0.99935 correlation coefficient in the comparison against ICP-MS method). © 2010 Elsevier B.V.
AB - Two PVC membrane ion selective electrodes for Pb(II) ion based on two bis-thioureas: 1,3-bis(N'-benzoylthioureido)benzene and 1,3-bis(N'-furoylthioureido)benzene as ionophores, are reported. A first membrane formulated using 1,3-bis(N'-benzoylthioureido)benzene as carrier exhibited a Nernstian response to Pb(II) over a wide concentration range (4.0×10 -6 to 1.0×10 -2 M) with a slope of 31.5±1.6mV/dec. It showed a fast response time (t 90% =14s) and could be used for 10 weeks without any divergence in potentials. The membrane formulated using 1,3-bis(N'-furoylthioureido)benzene as carrier exhibited a Nernstian response in the concentration range (5.0×10 -6 to 1.0×10 -2 M), with a slope of 30.0±1.3mV/dec. Its response time was t 90% =14s, and it could be used for 14 weeks without any divergence in potentials. The two proposed potentiometric sensors revealed acceptable selectivities for Pb(II) over a wide variety of other metal ions and could be used in a pH range of 2.2-6.0. Both electrodes were assayed in direct potentiometric determination of lead in soils (10-30mg/kg range) with very good performance (0.99935 correlation coefficient in the comparison against ICP-MS method). © 2010 Elsevier B.V.
KW - Bis-thiourea
KW - Lead ion selective electrode
KW - Potentiometric sensor
KW - PVC membrane
U2 - 10.1016/j.jhazmat.2010.04.107
DO - 10.1016/j.jhazmat.2010.04.107
M3 - Article
SN - 0304-3894
VL - 181
SP - 140
EP - 146
JO - Journal of Hazardous Materials
JF - Journal of Hazardous Materials
IS - 1-3
ER -