TY - JOUR
T1 - Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors
AU - Baixeras, C.
AU - García, I.
AU - Fernández, F.
AU - Domingo, C.
AU - Vidal-Quadras, A.
AU - Piesch, E.
PY - 1991/1/1
Y1 - 1991/1/1
N2 - A passive dosemeter, based on Makrofol ED track detectors covered with aluminized Mylar, enclosed in the Karlsruhe diffussion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a 241Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the NRPB Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have, also, been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. © 1991.
AB - A passive dosemeter, based on Makrofol ED track detectors covered with aluminized Mylar, enclosed in the Karlsruhe diffussion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a 241Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the NRPB Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have, also, been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. © 1991.
KW - alpha tracks
KW - calibration factor
KW - dosemeter for radon
KW - electrochemical etching
KW - Makrofol
KW - radon concentration
UR - https://www.scopus.com/pages/publications/0025893513
U2 - 10.1016/1359-0189(91)90193-L
DO - 10.1016/1359-0189(91)90193-L
M3 - Article
SN - 1359-0189
VL - 19
SP - 279
EP - 282
JO - International Journal of Radiation Applications and Instrumentation. Part
JF - International Journal of Radiation Applications and Instrumentation. Part
IS - 1-4
ER -