TY - JOUR
T1 - Feasibility and variability of corneal esthesiometry in Hermann's tortoises (Testudo hermanni) depending on age and body weight
AU - Gogova, Savina
AU - Leiva, Marta
AU - Melero, Adrián
AU - Martínez-Silvestre, Albert
AU - Ríos, Jose
AU - Peña, María Teresa
N1 - Funding Information:
The authors would like to thank Dr. ?ngel Ortill?s (Servei d'Oftalmologia de la Fundaci? Hospital Cl?nic Veterinari, Facultat de Veterin?ria, Universitat Aut?noma de Barcelona, Bellaterra Barcelona, Spain) for his expert help with the statistical analysis.
Publisher Copyright:
© 2020 Elsevier Inc.
Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2020/10
Y1 - 2020/10
N2 - Background: Hermann's tortoise is one of the most popular reptiles kept as pet which underlines the importance to reinforce the information needed to provide advanced and adequate veterinary care in exotic animal species. Therefore, the purpose of this study, performed in Testudo hermanni, was to evaluate corneal touch threshold (CTT) and its feasibility according to age and body weight. Methods: Fifty-one healthy tortoises were classified in 2 groups (≤2 years [young; n = 25] and 8–10 years [subadult; n = 26]). Central CTT was measured by means of a Cochet-Bonnet esthesiometer and defined as the filament length required to elicit a blink in at least 3/5 applications. CTT feasibility according to body weight was also evaluated by diving the individuals in weight groups consisting of “lighter” (<400 g [n = 31]) and “heavier” (≥400 g [n = 20]) animals. Results: Mean CTT was 5.99 cm for the whole population (90% CI: 5.87–6.11), being 5.98 cm for young (90% CI: 5.81–6.15) and 6 cm for all subadult (90% CI: 6.00–6.00) tortoises, and 5.98 cm for lighter (90% CI: 5.84–6.13) and 6 cm for all heavier (90% CI: 6.00–6.00) tortoises. No statistical differences were detected between age and weight groups (P = 0.159 and P = 0.159, respectively). Three animals presented unilateral faint fluorescein uptake postesthesiometry (3/51; 2.9%) that resolved spontaneously within 48 hours. Conclusions and clinical relevance: Cochet-Bonnet esthesiometer was a safe means of confirming high corneal sensitivity in all tortoises, which was high regardless of age. Increasing filament lengths would ultimately be required to determine the true corneal sensitivity scope of Testudo hermanni.
AB - Background: Hermann's tortoise is one of the most popular reptiles kept as pet which underlines the importance to reinforce the information needed to provide advanced and adequate veterinary care in exotic animal species. Therefore, the purpose of this study, performed in Testudo hermanni, was to evaluate corneal touch threshold (CTT) and its feasibility according to age and body weight. Methods: Fifty-one healthy tortoises were classified in 2 groups (≤2 years [young; n = 25] and 8–10 years [subadult; n = 26]). Central CTT was measured by means of a Cochet-Bonnet esthesiometer and defined as the filament length required to elicit a blink in at least 3/5 applications. CTT feasibility according to body weight was also evaluated by diving the individuals in weight groups consisting of “lighter” (<400 g [n = 31]) and “heavier” (≥400 g [n = 20]) animals. Results: Mean CTT was 5.99 cm for the whole population (90% CI: 5.87–6.11), being 5.98 cm for young (90% CI: 5.81–6.15) and 6 cm for all subadult (90% CI: 6.00–6.00) tortoises, and 5.98 cm for lighter (90% CI: 5.84–6.13) and 6 cm for all heavier (90% CI: 6.00–6.00) tortoises. No statistical differences were detected between age and weight groups (P = 0.159 and P = 0.159, respectively). Three animals presented unilateral faint fluorescein uptake postesthesiometry (3/51; 2.9%) that resolved spontaneously within 48 hours. Conclusions and clinical relevance: Cochet-Bonnet esthesiometer was a safe means of confirming high corneal sensitivity in all tortoises, which was high regardless of age. Increasing filament lengths would ultimately be required to determine the true corneal sensitivity scope of Testudo hermanni.
KW - Age difference
KW - Chelonian
KW - Corneal health
KW - Corneal sensitivity
KW - Corneal touch threshold
UR - https://www.scopus.com/pages/publications/85090358438
U2 - 10.1053/j.jepm.2020.07.004
DO - 10.1053/j.jepm.2020.07.004
M3 - Artículo
AN - SCOPUS:85090358438
SN - 1557-5063
VL - 35
SP - 82
EP - 86
JO - Journal of Exotic Pet Medicine
JF - Journal of Exotic Pet Medicine
ER -