Resum
Background: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. Methods: Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. Results: Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. Conclusions: In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.
Idioma original | English |
---|---|
Número d’article | 20 |
Revista | Journal of Cardiovascular Magnetic Resonance |
Volum | 24 |
Número | 1 |
DOIs | |
Estat de la publicació | Publicada - 28 de març 2022 |
Fingerprint
Navegar pels temes de recerca de 'False lumen rotational flow and aortic stiffness are associated with aortic growth rate in patients with chronic aortic dissection of the descending aorta: a 4D flow cardiovascular magnetic resonance study'. Junts formen un fingerprint únic.Conjunts de dades
-
The association of the Activities of Daily Living and the outcome of old intensive care patients suffering from COVID-19
Bruno, R. R. (Creador), Wernly, B. (Creador), Flaatten, H. (Creador), Fjølner, J. (Creador), Artigas Raventós, A. (Creador), Baldia, P. H. (Creador), Binneboessel, S. (Creador), Bollen Pinto, B. (Creador), Schefold, J. C. (Creador), Wolff, G. (Creador), Kelm, M. (Creador), Beil, M. (Creador), Sviri, S. (Creador), van Heerden, P. V. (Creador), Szczeklik, W. (Creador), Elhadi, M. (Creador), Joannidis, M. (Creador), Oeyen, S. (Creador), Kondili, E. (Creador), Marsh, B. (Creador), Wollborn, J. (Creador), Andersen, F. H. (Creador), Moreno, R. (Creador), Leaver, S. (Creador), Boumendil, A. (Creador), De Lange, D. W. (Creador), Guidet, B. (Creador) & Jung, C. (Creador), figshare, 19 de març 2022
DOI: 10.6084/m9.figshare.c.5904436.v1, https://springernature.figshare.com/collections/The_association_of_the_Activities_of_Daily_Living_and_the_outcome_of_old_intensive_care_patients_suffering_from_COVID-19/5904436/1
Conjunt de dades: Datasets
-
False lumen rotational flow and aortic stiffness are associated with aortic growth rate in patients with chronic aortic dissection of the descending aorta: a 4D flow cardiovascular magnetic resonance study
Ruiz-Muñoz, A. (Creador), Guala, A. (Creador), Dux-Santoy, L. (Creador), Teixidó-Turà, G. (Creador), Servato, M. L. (Creador), Valente, F. (Creador), Garrido-Oliver, J. (Creador), Galian-Gay, L. (Creador), Gutiérrez, L. (Creador), Fernandez-Galera, R. (Creador), Casas, G. (Creador), González-Alujas, T. (Creador), Cuéllar-Calabria, H. (Creador), Johnson, K. M. (Creador), Wieben, O. (Creador), Ferreira-Gonzalez, I. (Creador), Evangelista, A. (Creador) & Rodriguez-Palomares, J. (Creador), figshare, 29 de març 2022
DOI: 10.6084/m9.figshare.c.5919536.v1, https://springernature.figshare.com/collections/False_lumen_rotational_flow_and_aortic_stiffness_are_associated_with_aortic_growth_rate_in_patients_with_chronic_aortic_dissection_of_the_descending_aorta_a_4D_flow_cardiovascular_magnetic_resonance_study/5919536/1
Conjunt de dades: Datasets