TY - JOUR
T1 - Evaluation of two nonisotopic immunoassays for determination of glutamic acid decarboxylase and tyrosine phosphatase autoantibodies in serum
AU - Palomer, Xavier
AU - Mauricio, Dídac
AU - Rodríguez-Espinosa, José
AU - Zapico, Edgar
AU - Mayoral, Carme
AU - González-Sastre, Francesc
AU - De Leiva, Alberto
AU - Blanco-Vaca, Francisco
PY - 2004/8
Y1 - 2004/8
N2 - Background: Autoantibodies for the 65-kDa form of glutamic acid decarboxylase (GAD65) and protein tyrosine phosphatase-like protein (IA-2) are measured for risk prediction and diagnosis of autoimmune diabetes mellitus. There is a lack of adequate nonisotopic alternatives to the most widely used method for both autoantibodies, which is a radiobinding assay (RBA). Methods: We compared two commercially available immunoassays, an ELISA and a time-resolved immunofluorometric assay (TR-IFMA), with RBA. Results: We found excellent agreement between the RBA and ELISA for measurement of GAD65 autoantibodies (GADAs); they showed comparable analytical precision in the cutoff range and achieved similar diagnostic specificity. The ELISA identified more GADA-positive individuals among patients with new-onset type 1 diabetes than did the RBA [89% (95% confidence interval, 78-95%), vs 71% (58-82%); P <0.03]. For IA-2 autoantibodies (IA-2As), only the TR-IFMA achieved analytical performance and diagnostic accuracy comparable to that of the RBA. These results with the GADA ELISA and IA-2A TR-IFMA were consistent with those obtained blindly in the Diabetes Antibody Standardization Program 2003. The performance of the GADA TR-IFMA and IA-2A ELISA was unsatisfactory, and these tests were not subjected to clinical evaluation. Conclusions: The GADA ELISA and IA-2A TR-IFMA behave comparably with RBA and are thus suitable for use in the clinical laboratory.
AB - Background: Autoantibodies for the 65-kDa form of glutamic acid decarboxylase (GAD65) and protein tyrosine phosphatase-like protein (IA-2) are measured for risk prediction and diagnosis of autoimmune diabetes mellitus. There is a lack of adequate nonisotopic alternatives to the most widely used method for both autoantibodies, which is a radiobinding assay (RBA). Methods: We compared two commercially available immunoassays, an ELISA and a time-resolved immunofluorometric assay (TR-IFMA), with RBA. Results: We found excellent agreement between the RBA and ELISA for measurement of GAD65 autoantibodies (GADAs); they showed comparable analytical precision in the cutoff range and achieved similar diagnostic specificity. The ELISA identified more GADA-positive individuals among patients with new-onset type 1 diabetes than did the RBA [89% (95% confidence interval, 78-95%), vs 71% (58-82%); P <0.03]. For IA-2 autoantibodies (IA-2As), only the TR-IFMA achieved analytical performance and diagnostic accuracy comparable to that of the RBA. These results with the GADA ELISA and IA-2A TR-IFMA were consistent with those obtained blindly in the Diabetes Antibody Standardization Program 2003. The performance of the GADA TR-IFMA and IA-2A ELISA was unsatisfactory, and these tests were not subjected to clinical evaluation. Conclusions: The GADA ELISA and IA-2A TR-IFMA behave comparably with RBA and are thus suitable for use in the clinical laboratory.
UR - https://www.scopus.com/pages/publications/3242774581
U2 - 10.1373/clinchem.2004.031799
DO - 10.1373/clinchem.2004.031799
M3 - Article
C2 - 15155543
AN - SCOPUS:3242774581
SN - 0009-9147
VL - 50
SP - 1378
EP - 1382
JO - Clinical Chemistry
JF - Clinical Chemistry
IS - 8
ER -