TY - JOUR
T1 - Disposable magnetic DNA sensors for the determination at the attomolar level of a specific Enterobacteriaceae family gene
AU - Loaiza, Óscar A.
AU - Campuzano, Susana
AU - Pedrero, María
AU - Pividori, M. Isabel
AU - García, Pedro
AU - Pingarrón, José M.
PY - 2008/11/1
Y1 - 2008/11/1
N2 - Disposable magnetic DNA sensors using an enzyme-amplified strategy for the specific detection of a gene related to the Enterobacteriaceae bacterial family, based on the coupling of streptavidin-peroxidase to biotinylated lacZ gene target sequences, has been developed. A biotinylated 25-mer capture probe was attached to streptavidin-modified magnetic beads and hybridization with the biotinylated target was allowed to proceed. Then, a streptavidin-peroxidase polymer was attached to the biotinylated target, and the resulting modified magnetic beads were captured by a magnetic field on the surface of tetrathiafulvalene (TTF) modified gold screen-printed electrodes (Au/SPEs). The amperometric response obtained at -0.15 V after the addition of hydrogen peroxide was used to detect the hybridization process. In order to improve the sensitivity of the determination and reduce the assay time, different variables of the assay protocol were optimized. A low detection limit (5.7 fmol) with good stability (RSD = 7.1%, n = 10) was obtained. The DNA nonspecific adsorption at the magnetic beads was negligible, the obtained results thus demonstrating the possibility to detect the hybridization event with great specificity and sensitivity. The developed method was used for the analysis of Escherichia coli DNA fragments (326 bases) in polymerase chain reaction (PCR) amplicons extracted from a cell culture. As low as 2.5 aM asymmetric PCR product could be detected with the developed methodology. © 2008 American Chemical Society.
AB - Disposable magnetic DNA sensors using an enzyme-amplified strategy for the specific detection of a gene related to the Enterobacteriaceae bacterial family, based on the coupling of streptavidin-peroxidase to biotinylated lacZ gene target sequences, has been developed. A biotinylated 25-mer capture probe was attached to streptavidin-modified magnetic beads and hybridization with the biotinylated target was allowed to proceed. Then, a streptavidin-peroxidase polymer was attached to the biotinylated target, and the resulting modified magnetic beads were captured by a magnetic field on the surface of tetrathiafulvalene (TTF) modified gold screen-printed electrodes (Au/SPEs). The amperometric response obtained at -0.15 V after the addition of hydrogen peroxide was used to detect the hybridization process. In order to improve the sensitivity of the determination and reduce the assay time, different variables of the assay protocol were optimized. A low detection limit (5.7 fmol) with good stability (RSD = 7.1%, n = 10) was obtained. The DNA nonspecific adsorption at the magnetic beads was negligible, the obtained results thus demonstrating the possibility to detect the hybridization event with great specificity and sensitivity. The developed method was used for the analysis of Escherichia coli DNA fragments (326 bases) in polymerase chain reaction (PCR) amplicons extracted from a cell culture. As low as 2.5 aM asymmetric PCR product could be detected with the developed methodology. © 2008 American Chemical Society.
UR - https://www.scopus.com/pages/publications/55549093410
U2 - 10.1021/ac801319b
DO - 10.1021/ac801319b
M3 - Article
SN - 0003-2700
VL - 80
SP - 8239
EP - 8245
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 21
ER -