TY - JOUR
T1 - Diagnostic yield of specific inhalation challenge in hypersensitivity pneumonitis
AU - Muñoz, Xavier
AU - Sánchez-Ortiz, Mónica
AU - Torres, Ferran
AU - Villar, Ana
AU - Morell, Ferran
AU - Cruz, María Jesús
PY - 2014/1/1
Y1 - 2014/1/1
N2 - © 2014 ERS. Reliablemethods are needed to diagnose hypersensitivity pneumonitis. The aim of the study was to establish the diagnostic yield of specific inhalation challenge (SIC) in patients with hypersensitivity pneumonitis. All patients with suspected hypersensitivity pneumonitis in whom SIC was performed (n5113) were included. SIC was considered positive when patients showed a decrease of >15% in forced vital capacity (FVC) or >20% in diffusing capacity of the lung for carbon dioxide, or a decrease of 10% to 15% in FVC accompanied by a temperature increase of 0.5°C within 24 h of inhalation of the antigen. SIC was positive to the agents tested in 68 patients: 64 received a diagnosis of hypersensitivity pneumonitis and SIC results were considered false-positive in the remaining four patients. In the SICnegative group (n545), 24 patients received a diagnosis of hypersensitivity pneumonitis and SIC results were considered false-negative, and 21 patients were diagnosed with other respiratory diseases. The sensitivity and specificity of the test were 72.7% and 84%, respectively. Having hypersensitivity pneumonitis caused by an antigen other than birds or fungi predicted a false-negative result (p=0.001). In hypersensitivity pneumonitis, positive SIC testing virtually confirms the diagnosis, whereas negative testing does not rule it out, especially when the antigenic sources are not birds or fungi.
AB - © 2014 ERS. Reliablemethods are needed to diagnose hypersensitivity pneumonitis. The aim of the study was to establish the diagnostic yield of specific inhalation challenge (SIC) in patients with hypersensitivity pneumonitis. All patients with suspected hypersensitivity pneumonitis in whom SIC was performed (n5113) were included. SIC was considered positive when patients showed a decrease of >15% in forced vital capacity (FVC) or >20% in diffusing capacity of the lung for carbon dioxide, or a decrease of 10% to 15% in FVC accompanied by a temperature increase of 0.5°C within 24 h of inhalation of the antigen. SIC was positive to the agents tested in 68 patients: 64 received a diagnosis of hypersensitivity pneumonitis and SIC results were considered false-positive in the remaining four patients. In the SICnegative group (n545), 24 patients received a diagnosis of hypersensitivity pneumonitis and SIC results were considered false-negative, and 21 patients were diagnosed with other respiratory diseases. The sensitivity and specificity of the test were 72.7% and 84%, respectively. Having hypersensitivity pneumonitis caused by an antigen other than birds or fungi predicted a false-negative result (p=0.001). In hypersensitivity pneumonitis, positive SIC testing virtually confirms the diagnosis, whereas negative testing does not rule it out, especially when the antigenic sources are not birds or fungi.
U2 - 10.1183/09031936.00060714
DO - 10.1183/09031936.00060714
M3 - Article
SN - 0903-1936
VL - 44
SP - 1658
EP - 1665
JO - European Respiratory Journal
JF - European Respiratory Journal
IS - 6
ER -