TY - JOUR
T1 - Determination of polyethoxylated non-ionic surfactants using potentiometric flow injection systems. Improvement of the detection limits employing an on-line pre-concentration stage
AU - Martínez-Barrachina, Sílvia
AU - Del Valle, Manuel
AU - Matia, Lleonard
AU - Prats, Ramón
AU - Alonso, Julián
PY - 2002/3/11
Y1 - 2002/3/11
N2 - In this paper, the universal determination of non-ionic surfactants (NIS) of the polyethoxylate type is attempted using flow-injection potentiometry. Two systems are proposed which use specifically developed tubular flow-through ion selective electrodes (ISEs). These are sensitive to NIS with an hydrophilic chain between 6 and 18 ethoxylate units, which are predominant species in the environment. An on-line pre-concentration system is designed with the aim of a possible application for the unattended monitoring of NIS in surface waters. This on-line pre-concentration is achieved by employing a column packed with a commercial solid phase extraction (SPE) sorbent for the enrichment and purification of the target analytes. The procedure outlined improves the detection limit of a direct system, decreasing it from 1 × 10-4 to 3 × 10-6 M by use of a pre-concentration volume of 40.0 ml and 200 μl of 75% acetonitrile in water as the eluent. Precision was estimated as 4% relative standard deviation (R.S.D.) (n = 25) for a 1 × 10-6 M (0.7 ppm) nonylphenol polyethoxylate with 12 ethoxylate units when 10.0 ml of sample are pre-concentrated. Finally, the on-line pre-concentration system is applied for the total NIS determination in environmental samples from Llobregat river basin of Barcelona area (NE Spain). © 2002 Elsevier Science B.V. All rights reserved.
AB - In this paper, the universal determination of non-ionic surfactants (NIS) of the polyethoxylate type is attempted using flow-injection potentiometry. Two systems are proposed which use specifically developed tubular flow-through ion selective electrodes (ISEs). These are sensitive to NIS with an hydrophilic chain between 6 and 18 ethoxylate units, which are predominant species in the environment. An on-line pre-concentration system is designed with the aim of a possible application for the unattended monitoring of NIS in surface waters. This on-line pre-concentration is achieved by employing a column packed with a commercial solid phase extraction (SPE) sorbent for the enrichment and purification of the target analytes. The procedure outlined improves the detection limit of a direct system, decreasing it from 1 × 10-4 to 3 × 10-6 M by use of a pre-concentration volume of 40.0 ml and 200 μl of 75% acetonitrile in water as the eluent. Precision was estimated as 4% relative standard deviation (R.S.D.) (n = 25) for a 1 × 10-6 M (0.7 ppm) nonylphenol polyethoxylate with 12 ethoxylate units when 10.0 ml of sample are pre-concentrated. Finally, the on-line pre-concentration system is applied for the total NIS determination in environmental samples from Llobregat river basin of Barcelona area (NE Spain). © 2002 Elsevier Science B.V. All rights reserved.
KW - Alkylphenol polyethoxylates
KW - Ion selective electrodes
KW - On-line pre-concentration
KW - Potentiometric flow injection system
KW - Solid phase extraction
UR - https://www.scopus.com/pages/publications/0037060969
U2 - 10.1016/S0003-2670(01)01572-0
DO - 10.1016/S0003-2670(01)01572-0
M3 - Article
SN - 0003-2670
VL - 454
SP - 217
EP - 227
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
IS - 2
ER -