TY - JOUR
T1 - Cut-off values of myocardial perfusion gated-SPECT phase analysis parameters of normal subjects, and conduction and mechanical cardiac diseases
AU - Romero-Farina, Guillermo
AU - Aguadé-Bruix, Santiago
AU - Candell-Riera, Jaume
AU - Pizzi, María N.
AU - García-Dorado, David
PY - 2015/12/1
Y1 - 2015/12/1
N2 - © 2015, American Society of Nuclear Cardiology. Background: The aim of this study was to determine the cut-off values of gated myocardial perfusion rest SPECT phase analysis parameters of normal subjects, and conduction (CCD) and mechanical cardiac diseases (MCD). Methods: We prospectively analyzed 455 patients by means of phase analysis using SyncTool™ (Emory Cardiac Toolbox™). Of these, 150 corresponded to the control group (group 1, normal subjects) and 305 corresponded to patients with cardiac diseases (group 2, 63 with only CCD, 121 with only MCD, and 121 with CCD plus MCD). The optimal cut-off (CO) values of the peak phase (P), standard deviation (SD), bandwidth (B), skewness (S), and kurtosis (K) for discriminating between normal and dyssynchrony were obtained. Results: In order to differentiate group 1 from group 2, CO of SD > 18.4 and CO of B > 51 were the most sensitive parameters (75.7%, 95% CI 70.5%-80.4%, and 78.7%, 95% CI 73.7%-83.1%, respectively), and CO of S ≤ 3.2 and CO of K ≤ 9.3 were the most specific (92%, 95% CI 86.4%-95.8%, and 94.7%, 95% CI 89.8%-97.7%, respectively). In order to differentiate patients with CCD and MCD, CO values were SD > 26.1, B > 70, S ≤ 2.89, and K ≤ 10.2. In order to differentiate between patients with (n: 26) and without (n: 216) criteria of cardiac resynchronization therapy, CO values were SD > 40.2, B > 132, S ≤ 2.3, and K ≤ 4.6. Conclusions: In this pilot study, different CO values of phase histogram parameters were observed between normal subjects and patients with conduction and MCD, and between patients with and without criteria of cardiac resynchronization therapy.
AB - © 2015, American Society of Nuclear Cardiology. Background: The aim of this study was to determine the cut-off values of gated myocardial perfusion rest SPECT phase analysis parameters of normal subjects, and conduction (CCD) and mechanical cardiac diseases (MCD). Methods: We prospectively analyzed 455 patients by means of phase analysis using SyncTool™ (Emory Cardiac Toolbox™). Of these, 150 corresponded to the control group (group 1, normal subjects) and 305 corresponded to patients with cardiac diseases (group 2, 63 with only CCD, 121 with only MCD, and 121 with CCD plus MCD). The optimal cut-off (CO) values of the peak phase (P), standard deviation (SD), bandwidth (B), skewness (S), and kurtosis (K) for discriminating between normal and dyssynchrony were obtained. Results: In order to differentiate group 1 from group 2, CO of SD > 18.4 and CO of B > 51 were the most sensitive parameters (75.7%, 95% CI 70.5%-80.4%, and 78.7%, 95% CI 73.7%-83.1%, respectively), and CO of S ≤ 3.2 and CO of K ≤ 9.3 were the most specific (92%, 95% CI 86.4%-95.8%, and 94.7%, 95% CI 89.8%-97.7%, respectively). In order to differentiate patients with CCD and MCD, CO values were SD > 26.1, B > 70, S ≤ 2.89, and K ≤ 10.2. In order to differentiate between patients with (n: 26) and without (n: 216) criteria of cardiac resynchronization therapy, CO values were SD > 40.2, B > 132, S ≤ 2.3, and K ≤ 4.6. Conclusions: In this pilot study, different CO values of phase histogram parameters were observed between normal subjects and patients with conduction and MCD, and between patients with and without criteria of cardiac resynchronization therapy.
KW - cut-off values
KW - gated-SPECT myocardial perfusion imaging
KW - Left ventricular dyssynchrony
KW - phase analysis
U2 - 10.1007/s12350-015-0143-2
DO - 10.1007/s12350-015-0143-2
M3 - Article
SN - 1071-3581
VL - 22
SP - 1247
EP - 1258
JO - Journal of Nuclear Cardiology
JF - Journal of Nuclear Cardiology
IS - 6
ER -