Corrigendum: An Alternative Perfusion Approach for the Intensification of Virus-Like Particle Production in HEK293 Cultures (Front. Bioeng. Biotechnol., (2020), 8, (617), 10.3389/fbioe.2020.00617)

Jesús Lavado-García*, Laura Cervera, Francesc Gòdia

*Autor corresponent d’aquest treball

Producció científica: Contribució a revistaArticleRecercaAvaluat per experts

Resum

In the original article, there was a mistake in Figure 2 and its legend as published. The values 51.5 and 100 that appear in the figure and in section 2K of the legend should be 515 and 1000. The correct Figure 2 and its legend appears below. In the original article, there was also a mistake in Table 1 as published. The values 51.5 and 100 that appear in Table 1 for CSPR limits should be 515 and 1000. The corrected Table 1 appears below. In the original article, there was also an error in the text. The value of 3000 xg in the mentioned centrifugation should be 300 xg. A correction has been made to Section 2: Experimental, Sub-section 2.1: "HEK293 mammalian cell line, culture conditions," Paragraph 3: "For the pseudoperfusion experiments, the total culture volume was 20 ml and media replacement (MR) was carried out centrifuging the culture at 300 xg for 5 min every 12 h ensuring that the proportional volume of media was replaced depending on the condition. To maintain aMR rate of 2 reactor volume per day (RV/day), 20 ml were replaced every 12 h. For a rate of 1 RV/day, 10 ml were replaced every 12 h and for a rate of 0.5 RV/day, 5 ml were replaced every 12 h." Further, the value of 100 pL/cell/day should be 1000 pL/cell/day in accordance to the previous correction in Table 1 and Figure 2. A correction has been made to Section 3: Results and Discussion, Sub-section 3.2: "Optimization of retransfection by Design of Experiment (DoE) method," Paragraph 1: "As for the CSPR, the working range was set based on the previous study of the cell growth upon different media replacement rates. The upper limit was set at 1000 and the lower limit at 30 pL/cell/day." Finally, the value of 8.7·1011 VLP·L-1·day-1 should be 2.7·1012 VLP·L-1·day-1. This value is already correctly presented in Table 2.However, this typo was overlooked in the text when revising the manuscript. The value of 2.7·1012 VLP·L-1·day-1 is the one obtained in this work and 8.7·1011 is the one that it is being compared to. A correction has been made to Section 3: Results and Discussion, Sub-section 3.4: Intensification of the optimized protocol in bioreactor using ATF, Paragraph 1: "...the presented work achieved a reactor and media volumetric productivity of 7.1·1012 and 2.7·1012 VLP·L-1·day-1 respectively, improving 26.8% or 1.36 fold and 67.8% or 3.1 fold respectively." The authors apologize for these errors and state that this does not change the scientific conclusions of the article in any way. The original article has been updated. (Figure presented.) (Table presented.).

Idioma originalAnglès
Número d’article708773
RevistaFrontiers in Bioengineering and Biotechnology
Volum9
DOIs
Estat de la publicacióPublicada - 8 d’oct. 2021

Fingerprint

Navegar pels temes de recerca de 'Corrigendum: An Alternative Perfusion Approach for the Intensification of Virus-Like Particle Production in HEK293 Cultures (Front. Bioeng. Biotechnol., (2020), 8, (617), 10.3389/fbioe.2020.00617)'. Junts formen un fingerprint únic.

Com citar-ho