Resum
Purpose: To characterize the coagulation zones created by two radiofrequency (RF)-based hemostatic devices: one comprised an internally cooled monopolar electrode and the other comprised externally irrigated bipolar electrodes (saline-linked). Materials and methods: RF-induced coagulation zones were created on ex vivo and in vivo porcine models. Computer modeling was used to determine the RF power distribution in the saline-linked device. Results: Both external (irrigation) and internal cooling effectively prevented tissue sticking. Under ex vivo conditions in ‘painting’ application mode, coagulation depth increased with the applied power: 2.8 - 5.6 mm with the 3-mm monopolar electrode, 1.6 - 6.0 mm with the 5-mm monopolar electrode and 0.6 - 3.2 mm with the saline-linked bipolar electrodes. Under in vivo conditions and using spot applications, the 3-mm monopolar electrode created coagulation zones of similar depth to the saline-linked bipolar electrodes (around 3 mm), while the 5-mm monopolar electrode created deeper coagulations (4.5 - 6 mm) with less incidence of popping. The presence of saline around the saline-linked bipolar electrodes meant that a significant percentage of RF power (50 - 8ль) was dissipated by heating in the saline layer. Coagulation zones were histologically similar for all the tested devices. Conclusions: Both external (irrigation) and internal cooling in hemostatic RF devices effectively prevented tissue sticking and create similar coagulation zones from a histological point of view. Overall, saline-linked bipolar electrodes tend to create shallower coagulations than those created with an internally cooled monopolar electrode.
| Idioma original | Anglès |
|---|---|
| Pàgines (de-a) | 1397-1407 |
| Nombre de pàgines | 11 |
| Revista | International Journal of Hyperthermia |
| Volum | 39 |
| Número | 1 |
| DOIs | |
| Estat de la publicació | Publicada - 31 de des. 2022 |
Fingerprint
Navegar pels temes de recerca de 'Comparison of two radiofrequency-based hemostatic devices: saline-linked bipolar vs. cooled-electrode monopolar'. Junts formen un fingerprint únic.Projectes
- 1 Acabat
-
INVESTIGACION QUIRURGICA PARA TERAPIAS ABLATIVAS INNOVADORAS
Andaluz Martinez, A. M. (Investigador/a principal), Fondevila Palau, M. D. (Investigador/a), Garcia Arnas, F. A. (Investigador/a) & Moll Sanchez, J. (Investigador/a)
Ministerio de Economía y Competitividad (MINECO), Fons Europeu de Desenvolupament Regional (FEDER)
1/01/19 → 31/12/22
Projecte: Projectes i Ajuts a la Recerca
Com citar-ho
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver