TY - JOUR
T1 - Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies
T2 - a multicenter study in 21 Spanish pulmonology services
AU - Flandes, Javier
AU - Giraldo-Cadavid, Luis Fernando
AU - Alfayate, Javier
AU - Fernández-Navamuel, Iker
AU - Agusti, Carlos
AU - Lucena, Carmen M.
AU - Rosell, Antoni
AU - Andreo, Felipe
AU - Centeno, Carmen
AU - Montero, Carmen
AU - Vidal, Iria
AU - García-Alfonso, Lucía
AU - Bango, Antonio
AU - Ariza, Miguel
AU - Gallego, Rocío
AU - Orta, Marta
AU - Bello, Salvador
AU - Mincholé, Elisa
AU - Torrego, Alfons
AU - Pajares, Virginia
AU - González, Héctor
AU - Wangüemert, Aurelio Luis
AU - Pérez-Izquierdo, Julio
AU - Disdier, Carlos
AU - de Vega Sanchez, Blanca
AU - Cordovilla, Rosa
AU - Cascón, Juan
AU - Cruz, Antonio
AU - García-López, J. Javier
AU - Puente, Luis
AU - Benedetti, Paola
AU - García-Gallo, Cristina L.
AU - Díaz Nuevo, Gema
AU - Aguado, Silvia
AU - Partida, Concepción
AU - Díaz-Agero, Prudencio
AU - Luque Crespo, Estefanía
AU - Pavón, María
AU - Páez, Francisco
AU - Cases, Enrique
AU - Martínez, Raquel
AU - Briones, Andrés
AU - Fernández, Cleofe
AU - Martín Serrano, Concepción
AU - Uribe-Hernández, Ana Maria
AU - Robles, Jose
N1 - Publisher Copyright:
© 2020, The Author(s).
PY - 2020/12
Y1 - 2020/12
N2 - Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of central tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfied in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores > 70/100 from the first procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score. Conclusions: The aScope4™ scored well for ease of use, imaging, and aspiration. We found a learning curve with excellent scores from the 9th procedure. Bronchoscopists highlighted its portability, immediacy of use and the possibility of taking and storing images.
AB - Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of central tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfied in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores > 70/100 from the first procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score. Conclusions: The aScope4™ scored well for ease of use, imaging, and aspiration. We found a learning curve with excellent scores from the 9th procedure. Bronchoscopists highlighted its portability, immediacy of use and the possibility of taking and storing images.
KW - aScope4™
KW - Bronchoalveolar lavage
KW - Bronchoscopy
KW - CUSUM analysis
KW - Quality
UR - https://www.scopus.com/pages/publications/85097024716
U2 - 10.1186/s12931-020-01576-w
DO - 10.1186/s12931-020-01576-w
M3 - Article
C2 - 33267892
AN - SCOPUS:85097024716
SN - 1465-9921
VL - 21
JO - Respiratory Research
JF - Respiratory Research
IS - 1
M1 - 320
ER -